Urethane seam sealer SC
Great Adhesion | Single-Component | Fiber-Reinforced
Guardian Roof Polymers Urethane Seam Sealer SC is a fiber-reinforced mastic product for use on details and seams. It eliminates the need for three-course applications with embedded fabric, thus significantly reducing installation time. This single-component mastic also has a higher viscosity and sag resistance to conform around details and in vertical applications.
PACK SIZE
5 U.S. GAL (18.93 L)
COLOR
Gray
High Performance
Engineered for superior results
Advanced Protection
Protects against harsh conditions
Long Lasting
Built for extended durability
Low voc formulas
Safer for people and environment
Thinning
- Product should not be thinned.
Mixing
- If separation of the product is noticed, mix with a mechanical mixer before application to ensure uniform color and consistency.
SURFACE PREPARATION
- Surface must be clean, dry, and free of contaminants. Remove dust, dirt, oil, grease, and loose materials prior to application. Note: Do not wash asphaltic roof substrates prior to application.
- Remove rust and scale from metal surfaces with a wire brush.
- Slick, prefinished metal surfaces should be abraded with a wire brush or sandpaper, then wiped with a clean, dry rag.
APPLICATION INSTRUCTIONS
- Mix material prior to application.
- Apply to the patch area at a minimum wet thicknessof 1/16 in (1.5 mm). Spread the material at least 3 in(76.2 mm) in all directions beyond the affected area.
- For cold-weather applications (ambient temperaturebelow 40 °F (4 °C)): Store above 65 °F(18 °C) until the time of application
- Do not apply to substrates that are:
• Below 32°F (0°C)
• Above 120 °F (49 °C) - For filling deep pockets greater than 0.5 in (12.7 mm),a small amount of water (1 oz per gallon) may be added
DRY TIME
- At 1/16 in (1.5 mm) thick, in 75 °F (24 °C)temperatures and 55% relative humidity, product will betack-free in two (2) to four (4) hours and fully cured in forty(40) hours. Low humidity and low temperature will result inlonger cure times.
APPLICATION OF TOPCOAT
- Product may yellow with exposure to UV light and should be top-coated to extend the life of the material. A silicone, aliphatic urethane, or acrylic topcoat is recommended. Allow product to cure for sixteen (16) hours before applying a topcoat.
LIMITATIONS
- Not suitable for use over gravel-surfaced built-up roofs.
URETHANE SEAM SEALER SC
Color: GreyDANGER! HAZARD STATEMENT: Highly flammable liquid and vapor. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye irritation. May cause allergy or asthma symptoms or breathing difficulties if inhaled. May cause respiratory irritation. Suspected of causing cancer. Toxic to aquatic life. Harmful to aquatic life with long lasting effects. Hazard(s) not otherwise classified (HNOC): Harmful to aquatic life with long lasting effects.
PRECAUTIONS: Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Keep away from heat, hot surfaces/sparks/open flames/hot surfaces. No smoking. Keep container tightly closed. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapors/spray. Wash thoroughly after handling. Use only outdoors or in a well-ventilated area. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. In case of inadequate ventilation, wear respiratory protection.
RESPONSE: In case of fire: Use water fog, foam, dry chemical powder, carbon dioxide (CO2) to extinguish. Specific treatment (see Section 8 on this label). If on skin (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse. If skin irritation or a rash occurs: Get medical advice/attention. If inhaled: Remove person to fresh air and keep comfortable for breathing. If experiencing respiratory symptoms: Call a poison/doctor. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. Collect spillage.
STORAGE AND DISPOSAL: Store in a well-ventilated place. Keep container tightly closed. Keep cool. Store locked up. Dispose of contents and container in accordance with all local, regional, national and international regulations.
VOC CONCENTRATION: <50 g/L (<0.417 lb/gal) EPA Method 24 (as applied)
40% of the mixture consists of ingredients of unknown acute toxicity.This material is not known to contain any chemicals listed as a carcinogens or reproductive toxins. For more information go to www.P65Warnings.ca.gov.See Safety Data Sheet for further details regarding safe use of the product.
THIS PACKAGE FOR PROFESSIONAL/INDUSTRIAL USE ONLY. KEEP OUT OF REACH OF CHILDREN. REFER TO SDS FOR MORE INFORMATION.
Guardian Roof Polymers, Inc.
2851 Gold Tailings Ct., Rancho Cordova, CA 95670 916-447-2175
Manufactured in the U.S.A. with globally sourced materials.
For Chemical Emergency
Spill, Leak, Fire, Exposure, or Incident
CHEMTREC: Within USA and Canada: 1-800-424-9300 Outside USA and Canada: +1-703-527-3887 (collect calls accepted)